Gold Member Since 2016
Audited Supplier
SAFEE ELECTRIC EQUIPMENT CO., LIMITED

Pin Type, Glass Insulator, Suspension Insulator manufacturer / supplier in China, offering China Porcelain Pin Type Insulators 56-1, 56-2, 56-3, 56-4, 56-5 - China Pin Type Insulators, Insulators, China Metal Oxide Gapless Lightning Arrester (YH10W5-3), China 304 Stainless Steel Bolts and so on.

(/ )

Supplier Homepage Product Electric Fittings For Power Line Others Electric Fittings For Power Line China Porcelain Pin Type Insulators 56-1, 56-2, 56-3, 56-4, 56-5 - China Pin Type Insulators, Insulators

China Porcelain Pin Type Insulators 56-1, 56-2, 56-3, 56-4, 56-5 - China Pin Type Insulators, Insulators

FOB Price: US $5 / Piece
Min. Order: 2,000 Pieces
Min. Order FOB Price
2,000 Pieces US $5/ Piece
Get Latest Price
Port: Qingdao, China
Production Capacity: 5000pies/Days
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Application: Insulators, Electrical Winding Insulation, Winding Wire Coating Insulation, Electrical Base, Shell, Motor, Switch Baseplate
  • Chemistry: Organic Insulation
  • Thermal Rating: 250 250
  • Classification: Hybrid Insulation Materials
  • Color: Brown or Light Gray
  • Connection Method: Trough Type
  • OEM Service: Welcome
  • Usage: Electrical Installation
  • Quality Check: All Products Checked by Experienced QC
  • Transport Package: Carton, Pallet, Bag
  • Origin: Hebei China
  • Type: Insulation Tape
  • Material: Porcelain
  • Maximum Voltage: >100KV
  • Certification: UL, ISO9001, SGS
  • Brand: Safee
  • Delivery Date: 15days~35days After Order Confirmed
  • Structure: Suspension Insulator
  • Size of Bearing Capacity: 70kn to 210kn
  • Trademark: SAFEE
  • Specification: GB CE
Product Description
Product Description
porcelain spool insulator details and parameters
ANSI CLASS56-156-256-356-456-5
Fig. No.1212334
Main Dimension(mm)H146165191241318
h50.850.850.850.863.5
D191228267305343
d34.934.934.934.934.9
R11919191919
R21414141414
Leakage Distance (in)1317212734
Dry Arcing Distance (in)7891114
Low Frequency
Voltage
Dry Flashover95110125140175
Wet Flashover60708095125
Puncture130145165185225
Critical Impulse 
Flashover Voltage
Positive/kV150175200225270
Negative/kV190225265310340
Radio
Influence 
voltage
Test Voltage to ground/kV1522303044
Maximum RIV at 1000kHz/uVPlain800012000160001600025000
Radio Freed100100200200200
Cantilever Strength (lb)25003000300030003000


PRODUCT MODEL DESCRIPTION:
Conventional type:
p- pin insulator, the number after the dash indicating rated voltage (kv)
M- wooden arm angel
T-iron arm angel
model No.rated voltage (kv)dimensions (mm)nominal creepage distance (mm)bending load (kN)power frequency voltage(kv)50% full wave impulse flashover voltage
HDH1H2D1wet flashoverbreakdown
P-6T6901253030M16150-----------286570
P-6M690125140140M16150-----------286570
P-10T1010514515135M1619513.7329580
P-10M10105145151140M1619513.7329580
P-15T1512019016040M2028013.74598118
P-15M15120190160140M2028013.74598118
P-20T2016522824545M2037013.257111140
P-20M20165228245180M2037013.257111140
P-35T3520028028545M2056013.280156175
P-35M35200280285210M2056013.280156175

ANTI POLLUTION TYPE HIGH VOLTAGE LINE PIN INSULATOR
model No.rated voltage (kv)dimensions (mm)nominal crepage distance (mm)mechanical bending load (kN)power frequency voltqge (kv)lightning full wave impulse voltage (kv)
HDH1H2D1tolerancefailurewet flashoverbreakdown
PQ-10T161013314018340M162552.010.64013090
PQ-10T201013314018340M202552.010.64013090
PQ-10T202018517521040M203402.013.340145105

BS Porcelain Pin Type Insulator P-11-Y
Porcelain Insulator include pin type insulator  , suspension type ,post type insulator 
 
BS Porcelain Pin Type Insulator P-11-Y Specification
Fig.No.112363455
BS classP-11-YP-15-YP-22-YP-33-YP-35-YP-44-YPW-15-YPW-22-YPW-33-Y
Creepage distance, mm240298432630720864432673851
Dry arcing distance, mm102133200360399483197267419
Main dimension, mmH133137165244270318185255320
h484852.652.652.652.652.652.652.6
D140152229280270343170205240
d18.318.327.827.827.827.827.827.827.8
R1131319191419161616
R29.51114.3131414.3161616
Cantileveer Strength, KN111111131313111113
Min flashover voltagePower frequencyDry, KV7580100135140155100125140
Wet, KV505560951001106595110
Critical ImpulsePos, KV115130160180215240150190210
Neg, KV150175205290295305190235245
Withstand voltage1 min. power 
frequency
Dry, KV65709011011512590110125
Wet, KV40505575851006090100
Withstand voltage Impulse, KV90110150170190200140180200
RIV. DataTest volt. To gound151522303544223044
Max RIV at 1000HZ, UV8000800012000160001800025000120001600025000
Power frequency puncture voltage, KV150150200210230250150200210
Approx weight, kg1.8251112.5144.79.112.5


Ceramic Pin Insulator 55-2 type low voltage  porcelain  
Porcelain Insulator include pin type insulator  , suspension type ,post type insulator 
 
Ceramic Pin Insulator 55-2 type low voltage  porcelain Specification 
Class
ANSI

Main Dimension in (mm)

Leakage Distance

Min.Pin 
Length in (mm)

Gantilever 
Strength 1b (KN)

Flashover Voltage

Power 
Frequency Puncture
 Voltage Kv

Radio Influence Voltage
DH
Power Frequency

Impulse

Test Voltage
 TO Ground KV

Max RIVAt 1 MHz uv

Dry kv

Wet kv

Positive kv

Negative kv
55-13-1/4
(83)
3-1/2
(89)
4
(102)
4
(102)
3000
(13)
352050705052500/50
55-23-3/4
(95)
3-1/4
(83)
5
(127)
4
(102)
2500
(11)
50/452575/7095/857052500/50
55-34-3/4
(121)
3-3/4
(95)
7
(178)
5
(127)
2500
(11)
65/5535/30100/90130/11090105500/50
55-45-1/2
(140)
4-3/8
(111)
9
(229)
5
(127)
3000
(13)
70/6540/35110/105140/13095105500/50
55-57
(178)
4-7/8
(124)
12
(305)
6
(152)
3000
(13)
85/8045140/130170/150
ANSI type porcelain strain insulator
Specifications
1)porcelain strain insulator
2)ANSI standard strain insulator 
3)Strain insulator with cheap price
Service Condition
Ambient temperature-40°C~+40°C
AC power supply frequency ≤100 HZ
Earthquake intensity≤8
Altitude    ≤1500 m
Maximum wind velocity  ≤35 m/s


Description
Strain insulator - A dead end or anchor pole or tower is used where a straight section of line ends, or angles off in another direction. These poles must withstand the lateral (horizontal) tension of the long straight section of wire. In order to support this lateral load, strain insulators are used. For low voltage lines (less than 11 kV), shackle insulators are used as strain insulators. However, for high voltage transmission lines, strings of cap-and-pin (disc) insulators are used, attached to the crossarm in a horizontal direction. When the tension load in lines is exceedingly high, such as at long river spans, two or more strings are used in parallel.
Send your message to this supplier
Avatar
Miss Marry
Sales Manager
*From:
To: Miss Marry
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category